<ErrorNumber>15328</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 2 timed out while aborting
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error should not occur during normal machine operation. If it does,
first try selecting the RESUME button on the workstation dialog box a few times.
If this does not make the problem go away, then select RESET PLATESETTER
RECORDER from the workstation SYSTEM pull-down menu. If the problem persists,
then Creo Service should be called.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error occurs if the stepper motor takes longer than five seconds to stop
after the red ABORT button is pressed or the TABLE ABORT or ABORT diagnostic
monitor commands are issued while the stepper motor is running. This error
should not occur during normal machine operation.
</text></DescriptionText>
</ServiceInformation>
<Cause>
Make sure that the red ABORT button is not pressed and then type RESUME.
If the procedure described in Operator Action does not correct the problem, then
the only remaining option is to reset the recorder.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../error_messages/22074.xml</LinkAddress><LinkTitle>E_ALE_STEP_ABORTED</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:02 2008 PST
</Updated>
<Links>
</Links>
</Error>